tofsims
packageThe tofsims
package is a toolbox for importing, processing and analysing Time-of-Flight Secondary Ion Mass Spectrometry (ToF-SIMS) data. It currently supports the two most common commercial instrument platforms.
ToF-SIMS is a well established mass spectrometry technique with impressive figures of merit for chemical imaging (Belu, Graham, and Castner 2003, Fletcher and Vickerman (2013)). However, due to a number of reasons, ToF-SIMS instruments are not common in life science labs and experiments are therefore usually performed at specialized facilities. The tofsims
package targets biologists and bioinformaticians who have their samples analyzed by a ToF-SIMS facility and need tools to analyze the obtained rawdata by temselves.
Other R packages availavle for processing and analysis of Imaging Mass Spectrometry (IMS) data are MALDIquant (Gibb and Strimmer 2012) and Caridnal (Bemis et al. 2015), however both without support for ToF-SIMS experiments. Outside of R, a non open-source package for Matlab (Graham 2014) and a commercial toolbox also for Matlab are the few options to the instrument manufacturers tools.
This vignette showcases a user session using the most common methods available in the tofsims
package.
The tofsims
package has import functions for both pre-processed binary files of type BIF/BIF6 and raw data from two popular ToF-SIMS platforms (ULVAC-Phi, IONTOF). The former are imported directly using the MassImage()
function with the select arguments ulvacbif or iontofbif. The latter require additional steps as shown in the figure below.
For the following session, an ‘ULVAC-Phi’ rawdata file is first imported as a spectrum. The binary file is stored in the /rawdata directory of tofsimsData package. The select argument of MassSpectra()
has the options ulvacraw and iontofraw:
library(tofsims)
library(tofsimsData)
### get path to raw data file
rawData<-system.file('rawdata', 'trift_test_001.RAW', package="tofsimsData")
### the following param will cause to run non parallel
library(BiocParallel)
register(SnowParam(workers=0), default=TRUE)
spectraImport<-MassSpectra(select = 'ulvacraw', analysisName = rawData)
show()
returns a summary of the created MassSpectra object and plot()
can be used to visualize the imported spectra:
## analysisName instrument no.spectra spectra.points total.ion.count
## 1 trift_test_001.RAW ulvacphi 1 162'255 2'033'289
## analysis
## 1 none
Functions for mass calibration can be used on-screen or with arguments for batch processing of multiple files. If no value argument is provided, the user is prompted in the plot window.
unitMassPeaks()
is used to construct a peaklist for image import. Functions for more advanced peak picking are described in the package and upcoming vignettes. However, for image data with low spectral resolution, unit mass resolution is often sufficient. When the lower
and/or upper
argument are/is left out, peak width at the chosen M/z’s (widthAt
) is chosen on-screen. The factor
argument allows choosing assymetric peak widths. Peak widths are interpolated linear between the two M/z chosen in widthAt
.
Now, the experiment can be imported with the peak list as image data followed by poisson scaling. Poisson scaling is commonly used on ToF-SIMS data (Keenan and Kotula 2004). Visualization of image data is by the image()
function.
Various multivariate analysis methods are implemented. Here, Principal Component Analysis (PCA) (Wold, Esbensen, and Geladi 1987) and Maximum Autocorrelation Factors (MAF) (Switzer and Green 1984) are shown. While PCA is used for dimension reduction in a wide range of applications, MAF is specifc for spatial datasets. Its usefulness has been demonstrated for ToF-SIMS imaging datasets (Henderson, Fletcher, and Vickerman 2009). Other methods available in the tofsims package are Multivariate Curve Resolution (MCR) (Jaumot and Tauler 2015) and Minimum Noise Fraction (MNF) (Stone et al. 2012).
The EBImage
package from Bioconductor (Pau et al. 2010) can be used for segmentation of ToF-SIMS image data. A typical workflow is to choose a principal component that contains chemical features of interest and convert it by threshholding into a black and white mask.
library(EBImage)
pcaScore3<-imageMatrix(analysis(imageImport, 1), comp=3)
pcaScore3Mask<-thresh(x = pcaScore3, h = 30, w = 30)
par(mar=c(0,0,0,0), oma=c(0,0,0,0))
image(pcaScore3Mask, col=c('white', 'black'))
The mask can be used directly for area quantitations.
paste(round(100/(xy(imageImport)[1]*xy(imageImport)[2])*sum(pcaScore3Mask),2),
' % of the image is Cell Wall')
## [1] "49.77 % of the image is Cell Wall"
The mask can also be modified by the tools available in EBImage
. Below the morphology operations ‘opening’ and ‘closing’ are shown.
opened<-opening(pcaScore3Mask, kern = makeBrush(3, shape = 'diamond'))
closed<-closing(pcaScore3Mask, kern = makeBrush(3, shape = 'diamond'))
par(mar=c(0,0,0,0), oma=c(0,0,0,0), mfcol=c(1,2))
image(opened, col = c('white', 'black'))
image(closed, col = c('white','black'))
Masks can then be applied back to the original image to select and visualize specific compound mass spectra. In the example below the ‘opened’ mask is applied on the original imported image. This operation removes all signal from the area which was shown white in the mask. Multiple masks, for example from different PCA components can as such be used for image segmentation.
Belu, Anna M., Daniel J. Graham, and David G. Castner. 2003. “Time-of-Flight Secondary Ion Mass Spectrometry: Techniques and Applications for the Characterization of Biomaterial Surfaces.” Biomaterials 24 (21):3635–53. https://doi.org/http://dx.doi.org/10.1016/S0142-9612(03)00159-5.
Bemis, Kyle D., April Harry, Livia S. Eberlin, Christina Ferreira, Stephanie M. van de Ven, Parag Mallick, Mark Stolowitz, and Olga Vitek. 2015. “Cardinal: An R Package for Statistical Analysis of Mass Spectrometry-Based Imaging Experiments.” Bioinformatics 31 (14):2418–20. https://doi.org/10.1093/bioinformatics/btv146.
Fletcher, John S., and John C. Vickerman. 2013. “Secondary Ion Mass Spectrometry: Characterizing Complex Samples in Two and Three Dimensions.” Analytical Chemistry 85 (2):610–39. https://doi.org/10.1021/ac303088m.
Gibb, Sebastian, and Korbinian Strimmer. 2012. “MALDIquant: A Versatile R Package for the Analysis of Mass Spectrometry Data.” Bioinformatics 28 (17). Oxford University Press:2270–1. https://doi.org/10.1093/bioinformatics/bts447.
Graham, Dan. 2014. “NBToolbox.” http://www.nb.uw.edu/mvsa/multivariate-surface-analysis-homepage.
Henderson, Alex, John S. Fletcher, and John C. Vickerman. 2009. “A Comparison of Pca and Maf for Tof-Sims Image Interpretation.” Surface and Interface Analysis 41 (8):666–74. https://doi.org/10.1002/sia.3084.
Jaumot, Joaquim, and Roma Tauler. 2015. “Potential Use of Multivariate Curve Resolution for the Analysis of Mass Spectrometry Images.” Analyst 140 (3). The Royal Society of Chemistry:837–46. https://doi.org/10.1039/C4AN00801D.
Keenan, Michael R., and Paul G. Kotula. 2004. “Accounting for Poisson Noise in the Multivariate Analysis of Tof-Sims Spectrum Images.” Surface and Interface Analysis 36 (3):203–12. https://doi.org/10.1002/sia.1657.
Pau, Grégoire, Florian Fuchs, Oleg Sklyar, Michael Boutros, and Wolfgang Huber. 2010. “EBImage—an R Package for Image Processing with Applications to Cellular Phenotypes.” Bioinformatics 26 (7):979–81. https://doi.org/10.1093/bioinformatics/btq046.
Stone, Glenn, David Clifford, Johan OR Gustafsson, Shaun R McColl, and Peter Hoffmann. 2012. “Visualisation in Imaging Mass Spectrometry Using the Minimum Noise Fraction Transform.” BMC Research Notes 5. BioMed Central:419–19. https://doi.org/10.1186/1756-0500-5-419.
Switzer, Paul, and Andrew A. Green. 1984. “Min/Max Autocorrelation Factors for Multivariate Spatial Imagery: Technical Report 6.” Stanford, California: Department of Statistics, Stanford University. https://statistics.stanford.edu/sites/default/files/SWI%20NSF%2006.pdf.
Wold, Svante, Kim Esbensen, and Paul Geladi. 1987. “Principal Component Analysis.” Chemometrics and Intelligent Laboratory Systems 2 (1–3):37–52. https://doi.org/http://dx.doi.org/10.1016/0169-7439(87)80084-9.